Installation Instructions
WARNING
Do not ground the circuit to a gas line.
Do not ground the circuit to a hot water pipe.
Water lines that are insulated must be jumped to
assure continuity to ground. See below.
Grounding Using an External Cold Water Pipe
GREEN
GREEN
WHITE
WHITE
BLACK
BLACK
UL/CSA approved
NEMA strain relief
Fasten clamp tightly
on metal pipe
Separate No. 10 (minimum)
copper ground wire
To house circuit breaker
or fuse box
To RNIVS
Wire nut,
3 places
Junction box
Metal Cold Water Pipe
(detail)
Clamps
Bare metal
Meter
No. 4 copper
wire
Grounding to a Cold Water Pipe
To ground the RNIVS to a cold water pipe, refer to the
images on this page.